User Manual U s e r M a n u a l Siqura A-80 Firmware Version 3.2 8-channel audio and contact closure card
Page 11 C h a p t e r 3 3 Product Description Siqura A-80 is an eight-channel audio and I/O card for IP applications. This chapter introduces th
Siqura A-80 Page 12 Open Streaming Architecture (OSA) The A-80 is designed to comply with the worldwide adopted standards for streaming audio. OSA o
Page 13 C h a p t e r 4 4 Installation This chapter describes how to power your A-80 unit and connect network and signal cables. In This Chapte
Siqura A-80 Page 14 4.3 Startup After startup, the DC LED will light and the network indicator lights will go through an on/off sequence. The power
Installation Page 15 Balanced and unbalanced audio connections The A-80 offers balanced audio inputs and unbalanced audio outputs. The following
Page 17 C h a p t e r 5 5 Connections Having installed the A-80, the next step is to establish an IP connection and set up audio and contact clo
Siqura A-80 Page 18 Step 1: Setting the host PC to the factory default subnet of the unit To configure the network adapter on the host PC 1. In
Connections Page 19 5.2 Making Audio and Contact Closure Connections Connection methods With the A-80's IP connection established, audio and
Page 2 Note: To ensure proper operation, please read this manual thoroughly before using the product and retain the information for future referenc
Page 21 C h a p t e r 6 6 Interfaces A variety of methods can be employed to communicate with the A-80. This chapter outlines the interfaces you
Siqura A-80 Page 22 The SNMP Agent is MIB-2 compliant and supports versions 1 and 2c of the SNMP protocol. The MIB database can be downloaded at www
Page 23 C h a p t e r 7 7 Accessing the Internal Web Server The web pages of the A-80 offer a user-friendly interface for configuring the unit&a
Siqura A-80 Page 24 A-80 login page Connect dialog box
Page 25 C h a p t e r 8 8 Web Page Features Navigation Menu Using the menu on the left of each web page you can navigate to the other web pages.
Siqura A-80 Page 26 Sections, buttons, and tabs Apart from the menu, the web pages share the following features. Sections showing parameter val
Page 27 C h a p t e r 9 9 Working with the Web Pages The A-80's web pages enable you to monitor the media streams the unit is handling and
Siqura A-80 Page 28 9.2 Status Status page: a snapshot with automatic page updating Tabs The Status page has two tabs: Status and Measurements.
Working with the Web Pages Page 29 9.2.2 Measurements Measurements tab: a snapshot with automatic page updating Measurements The Measurements t
Page 3 Contents 1 INTRODUCTION ...
Siqura A-80 Page 30 Note: The factory-set IP address of the unit is in the 10.x.x.x range with a subnet mask of 255.0.0.0. Achieving initial communi
Working with the Web Pages Page 31 9.4 Audio # Audio # page Enabling/Disabling audio Using the Enable check box at the top of the Audio page,
Siqura A-80 Page 32 Input Settings G711 μ-law. 1 ch. 8kHz. 64 kbit/s mainly used in USA mono, low quality used for Genetec's Omnicast
Working with the Web Pages Page 33 Highlighted fields The source address and port number fields are highlighted in green (as shown above) when the
Siqura A-80 Page 34 Audio Encoder Advanced Settings, Audio Encoder Audio Encoder Audio format PCM 16bit, A-law 8bit, μ-law 8bit. Audio Decode
Working with the Web Pages Page 35 Transmitter # Advanced Settings, Transmitter # Transmitter # DSCP field Range: [0...63]. DSCP (Differentia
Siqura A-80 Page 36 Receiver 1 Advanced Settings, Receiver 1 Receiver 1 Filter on source port Can be used to filter incoming signals. With multip
Working with the Web Pages Page 37 RTSP Transmitter Advanced Settings: RTSP Transmitter RTSP Transmitter DSCP field Range: [0...63]. DSCP (Dif
Siqura A-80 Page 38 SAP Settings The A-80 includes a SAP announcer. The Session Announcement Protocol is used to advertise that a media stream gen
Working with the Web Pages Page 39 9.4.2 FloodGuard Note on FloodGuard: FloodGuard is a stream control mechanism that can be enabled/disabled ind
Contents Page 4 9.6.5 Firmware ...
Siqura A-80 Page 40 Contact Closure Input # CC Input 1 settings Contact Closure Input # Input mode Normal Direction. Invert Force active Always o
Working with the Web Pages Page 41 9.5.1 Making Contact Closure Connections To make a contact closure connection On the Transmitter side, f
Siqura A-80 Page 42 CC Output # Settings, Receiver Advanced Settings, CC Output #, Receiver Receiver Source port filter Can be used to filter i
Working with the Web Pages Page 43 9.6 Device Management Device Management page, General tab The Device Management page has six tabs: General,
Siqura A-80 Page 44 9.6.1.1 Advanced Settings Device Management: Advanced Settings Alarm Settings Board temperature alarm A notification is iss
Working with the Web Pages Page 45 SNMP System Information The SNMP System Information section shows the network/device data specifically made ava
Siqura A-80 Page 46 9.6.3 MX Device Management: MX MX/IP MX/IP is a UDP protocol used to communicate with Siqura equipment over a network conne
Working with the Web Pages Page 47 9.6.4 Auto Discovery Device Management: Auto Discovery Advertising the A-80 on the network On the Auto Disc
Siqura A-80 Page 48 To view the A-80 device description in Device Spy 1. Start Device Spy. The network is scanned. A list of detected UPnP devic
Working with the Web Pages Page 49 To access the A-80's web pages via Device Spy 1. Start Device Spy. 2. In the right-hand panel, double
Page 5 C h a p t e r 1 1 Introduction Document scope This manual applies to A-80 v3.2, Siqura's 8-channel audio and contact closure card.
Siqura A-80 Page 50 Current version This section offers information on the currently active firmware version. Upgrade This section enables you to
Working with the Web Pages Page 51 9.6.6 Reboot Device Management: Reboot options Reboot Reboot Reboots the unit without resetting variabl
Siqura A-80 Page 52 9.7 User Management User Management: Web Access Tabs The User Management page is available to users with an Admin account.
Working with the Web Pages Page 53 To edit a user 1. On the User Management page, open the Web Access tab. 2. Select the user name from the U
Siqura A-80 Page 54 9.8 Date and Time Date and Time settings Date and Time The A-80 has a battery-supported real-time clock that can be adjusted
Page 55 C h a p t e r 10 10 Appendix: Multicasting, Multi-Unicasting, Port Numbers Multicasting The A-80 can be used in a multicasting setting.
Siqura A-80 Page 56 General Example Video 50xxx Video 50010 Audio 51xxx Audio 51010 Data 52xxx Data 1 52010 (RS-4xx) Data 2 52020 (RS-232) CC 53
Page 57 C h a p t e r 11 11 Appendix: Enabling JavaScript In order for the A-80 web pages to display correctly, JavaScript must be enabled in yo
Page 59 C h a p t e r 12 12 Appendix: Technical Specifications Siqura A-80 8-channel audio and contact closure card AUDIO Number of channels 8 (
Siqura A-80 Page 60 Siqura A-80 8-channel audio and contact closure card Stand-alone units (/SA) 11 to 19 VDC (PSA-12 DC/25 or PSR-12 DC) ENVIRONMEN
Page 7 C h a p t e r 2 2 Safety Information This chapter contains the A-80 safety instructions. In This Chapter Safety Information ...
Siqura A-80 Page 8 Optical Safety (A-80 /SFP) This optical equipment contains Class 1M lasers or LEDs and has been designed and tested to meet IEC 6
Safety Information Page 9 RoHS Statement Global concerns over the health and environmental risks associated with the use of certain environmental